Brought to you by SLGO, the St. Lawrence regional association of CIOOS |
Dataset Title: | OMDS-ADCP data | SGDO-Données ADCP |
Institution: | Fisheries and Oceans Canada (Dataset ID: mpoSgdoADCP) |
Information: | Summary | License | FGDC | ISO 19115 | Metadata | Background | Subset | Files | Make a graph |
Attributes { s { time { String _CoordinateAxisType "Time"; Float64 actual_range 8.961246e+8, 1.6985951990000021e+9; String axis "T"; String cf_role "profile_id"; String ioos_category "Time"; String long_name "Time"; String standard_name "time"; String time_origin "01-JAN-1970 00:00:00"; String units "seconds since 1970-01-01T00:00:00Z"; } latitude { String _CoordinateAxisType "Lat"; Float64 _FillValue -9999.0; Float64 actual_range 45.93898, 64.33323; String axis "Y"; Float64 colorBarMaximum 90.0; Float64 colorBarMinimum -90.0; String ioos_category "Location"; String long_name "Latitude"; String standard_name "latitude"; String units "degrees_north"; } longitude { String _CoordinateAxisType "Lon"; Float64 _FillValue -9999.0; Float64 actual_range -87.3499, -56.61817; String axis "X"; Float64 colorBarMaximum 180.0; Float64 colorBarMinimum -180.0; String ioos_category "Location"; String long_name "Longitude"; String standard_name "longitude"; String units "degrees_east"; } depth { String _CoordinateAxisType "Height"; String _CoordinateZisPositive "down"; Float64 _FillValue -9999.0; Float64 actual_range 0.28, 457.64; String axis "Z"; Float64 colorBarMaximum 8000.0; Float64 colorBarMinimum -8000.0; String colorBarPalette "TopographyDepth"; String coverage_content_type "coordinate"; String generic_name "depth"; String ioos_category "Location"; String legacy_GF3_code "SDN:GF3::DEPH"; String long_name "bin depth below surface"; String positive "down"; String sdn_P02_urn "SDN:P02::MPMN"; String sdn_parameter_name "Depth below surface of the water body by acoustic doppler current profiler (ADCP) and computation from traveltime averaged from all operational beams and unknown sound velocity profile"; String sdn_parameter_urn "SDN:P01::PPSAADCP"; String sdn_uom_name "Metres"; String sdn_uom_urn "SDN:P06::ULAA"; Float64 sensor_depth 0.0; String sensor_type "adcp"; String serial_number "8655"; String standard_name "depth"; String units "m"; } TEMPP901 { Float64 _FillValue -9999.0; Float64 actual_range -7.1, 23.63; String ancillary_variables "TEMPP901_QC"; Float64 bin_size 1.9999999999999998; Float64 colorBarMaximum 40.0; Float64 colorBarMinimum -10.0; String generic_name "temperature"; String legacy_GF3_code "SDN=GF3==TE90"; String long_name "temperature"; String sdn_parameter_name "Temperature of the water body"; String sdn_parameter_urn "SDN=P01==TEMPP901"; String sdn_uom_name "Celsius degree"; String sdn_uom_urn "SDN=P06==UPAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String units "degree_C"; Float64 xducer_offset_from_bottom 14.18; } TEMPP901_QC { Byte _FillValue 127; String _Unsigned "false"; Byte actual_range 0, 9; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing"; String flag_reference "BODC SeaDataNet"; Byte flag_values 0, 1, 2, 3, 4, 5, 9; String generic_name "temperature_QC"; String legacy_GF3_code "SDN:GF3::QQQQ"; String long_name "Quality flag for TEMPP901"; String sdn_parameter_name "QC flag"; String sdn_parameter_urn "SDN:P02::ACFL"; String standard_name "quality_flag"; } PTCHEI01 { Float64 _FillValue -9999.0; Float64 actual_range -47.4, 35.9; Float64 bin_size 1.9999999999999998; String generic_name "pitch"; String legacy_GF3_code "SDN=GF3==PTCH"; String long_name "pitch"; String sdn_parameter_name "Orientation (pitch) of measurement platform by inclinometer"; String sdn_parameter_urn "SDN=P01==PTCHEI01"; String sdn_uom_name "Degrees"; String sdn_uom_urn "SDN=P06==UAAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String standard_name "platform_pitch"; String units "degree"; Float64 xducer_offset_from_bottom 14.18; } PTCHEI01_QC { Byte _FillValue 127; String _Unsigned "false"; Byte actual_range 0, 0; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; } ROLLEI01 { Float64 _FillValue -9999.0; Float64 actual_range -74.2, 99.8; Float64 bin_size 1.9999999999999998; String generic_name "roll"; String legacy_GF3_code "SDN=GF3==ROLL"; String long_name "roll"; String sdn_parameter_name "Orientation (roll angle) of measurement platform by inclinometer"; String sdn_parameter_urn "SDN=P01==ROLLEI01"; String sdn_uom_name "Degrees"; String sdn_uom_urn "SDN=P06==UAAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String standard_name "platform_roll"; String units "degree"; Float64 xducer_offset_from_bottom 14.18; } ROLLEI01_QC { Byte _FillValue 127; String _Unsigned "false"; Byte actual_range 0, 9; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; } HEADCM01 { Float64 _FillValue -9999.0; Float64 actual_range -180.0, 380.5; Float64 bin_size 1.9999999999999998; String generic_name "heading"; String legacy_GF3_code "SDN=GF3==HEAD"; String long_name "heading"; String sdn_parameter_name "Orientation (horizontal relative to true north) of measurement device (heading)"; String sdn_parameter_urn "SDN=P01==HEADCM01"; String sdn_uom_name "Degrees"; String sdn_uom_urn "SDN=P06==UAAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String standard_name "platform_orientation"; String units "degree"; Float64 xducer_offset_from_bottom 14.18; } HEADCM01_QC { Byte _FillValue 127; String _Unsigned "false"; Byte actual_range 0, 4; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; } LCEWAP01 { Float64 _FillValue -9999.0; Float64 actual_range -99.9999, 999.9999; String ancillary_variables "LCEWAP01_QC"; Float64 bin_size 1.9999999999999998; Float64 colorBarMaximum 0.5; Float64 colorBarMinimum -0.5; String generic_name "u"; String legacy_GF3_code "SDN=GF3==EWCT"; String long_name "eastward sea water velocity"; String sdn_parameter_name "Eastward current velocity (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP)"; String sdn_parameter_urn "SDN=P01==LCEWAP01"; String sdn_uom_name "metres per second"; String sdn_uom_urn "SDN=P06==UVAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String standard_name "eastward_sea_water_velocity"; String units "m s-1"; Float64 xducer_offset_from_bottom 14.18; } LCEWAP01_QC { Byte _FillValue 127; String _Unsigned "false"; Byte actual_range 0, 9; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing"; String flag_reference "BODC SeaDataNet"; Byte flag_values 0, 1, 2, 3, 4, 5, 9; String generic_name "u_QC"; String legacy_GF3_code "SDN:GF3::QQQQ"; String long_name "Quality flag for LCEWAP01"; String sdn_parameter_name "QC flag"; String sdn_parameter_urn "SDN:P02::ACFL"; String standard_name "quality_flag"; } LCNSAP01 { Float64 _FillValue -9999.0; Float64 actual_range -99.9999, 999.9999; String ancillary_variables "LCNSAP01_QC"; Float64 bin_size 1.9999999999999998; Float64 colorBarMaximum 0.5; Float64 colorBarMinimum -0.5; String generic_name "v"; String legacy_GF3_code "SDN=GF3==NWCT"; String long_name "northward sea water velocity"; String sdn_parameter_name "Northward current velocity (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP)"; String sdn_parameter_urn "SDN=P01==LCNSAP01"; String sdn_uom_name "metres per second"; String sdn_uom_urn "SDN=P06==UVAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String standard_name "northward_sea_water_velocity"; String units "m s-1"; Float64 xducer_offset_from_bottom 14.18; } LCNSAP01_QC { Byte _FillValue 127; String _Unsigned "false"; Byte actual_range 0, 9; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing"; String flag_reference "BODC SeaDataNet"; Byte flag_values 0, 1, 2, 3, 4, 5, 9; String generic_name "v_QC"; String legacy_GF3_code "SDN:GF3::QQQQ"; String long_name "Quality flag for LCNSAP01"; String sdn_parameter_name "QC flag"; String sdn_parameter_urn "SDN:P02::ACFL"; String standard_name "quality_flag"; } LRZAAP01 { Float64 _FillValue -9999.0; Float64 actual_range -99.9999, 999.9999; String ancillary_variables "LRZAAP01_QC"; Float64 bin_size 1.9999999999999998; Float64 colorBarMaximum 0.5; Float64 colorBarMinimum -0.5; String generic_name "w"; String legacy_GF3_code "SDN=GF3==VCSP"; String long_name "upward sea water velocity"; String sdn_parameter_name "Upward current velocity (Eulerian measurement) in the water body by moored acoustic doppler current profiler (ADCP)"; String sdn_parameter_urn "SDN=P01==LRZAAP01"; String sdn_uom_name "metres per second"; String sdn_uom_urn "SDN=P06==UVAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String standard_name "upward_sea_water_velocity"; String units "m s-1"; Float64 xducer_offset_from_bottom 14.18; } LRZAAP01_QC { Byte _FillValue 127; String _Unsigned "false"; Byte actual_range 0, 9; Float64 colorBarMaximum 10.0; Float64 colorBarMinimum 0.0; String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing"; String flag_reference "BODC SeaDataNet"; Byte flag_values 0, 1, 2, 3, 4, 5, 9; String generic_name "w_QC"; String legacy_GF3_code "SDN:GF3::QQQQ"; String long_name "Quality flag for LRZAAP01"; String sdn_parameter_name "QC flag"; String sdn_parameter_urn "SDN:P02::ACFL"; String standard_name "quality_flag"; } LERRAP01 { Float64 _FillValue -9999.0; Float64 actual_range -99.9999, 999.9999; Float64 bin_size 1.9999999999999998; Float64 colorBarMaximum 0.1; Float64 colorBarMinimum 0.0; String generic_name "e"; String legacy_GF3_code "SDN=GF3==ERRV"; String long_name "error velocity in sea water"; String sdn_parameter_name "Current velocity error in the water body by moored acoustic doppler current profiler(ADCP)"; String sdn_parameter_urn "SDN=P01==LERRAP01"; String sdn_uom_name "metres per second"; String sdn_uom_urn "SDN=P06==UVAA"; Float64 sensor_depth 38.915; String sensor_type "Teledyne RD Instruments Inc."; Int32 serial_number 8655; String standard_name "error_velocity_in_sea_water"; String units "m s-1"; Float64 xducer_offset_from_bottom 14.18; } station { String long_name "Station Identifier"; } chief_scientist { } cruise_number { } id { String cf_role "timeseries_id"; String long_name "Original filename"; } } NC_GLOBAL { String cdm_data_type "TimeSeriesProfile"; String cdm_profile_variables "time"; String cdm_timeseries_variables "id"; String comment "Data combined from archived files"; String Conventions "CF-1.10, COARDS,tomcat/src/content/erddap/fragments/prod/mpoSgdoADCP.xml ACDD-1.3"; String coord_system "earth"; String country_code "Ca"; String country_institute_code "CaIML"; String creator_name "Institut Maurice-Lamontagne, Department of Fisheries and oceans Canada"; String creator_type "institution"; String data_type "madcp"; String defaultDataQuery "&time>=minTime&time<=maxTime"; Float64 Easternmost_Easting -56.61817; String event_number "NS3"; String event_start_time "2023-06-19T04:45:00Z"; String featureType "TimeSeriesProfile"; String flag_meanings "no_quality_control value_seems_correct value_appears_inconsistent_with_other_values value_seems_doubtful value_seems_erroneous value_was_modified value_missing"; Byte flag_values 0, 1, 2, 3, 4, 5, 9; String flags_reference "BODC SeaDataNet"; String frequency "WorkHorse"; Float64 geospatial_lat_max 64.33323; Float64 geospatial_lat_min 45.93898; String geospatial_lat_units "degrees_north"; Float64 geospatial_lon_max -56.61817; Float64 geospatial_lon_min -87.3499; String geospatial_lon_units "degrees_east"; Float64 geospatial_vertical_max 457.64; Float64 geospatial_vertical_min 0.28; String geospatial_vertical_positive "down"; String geospatial_vertical_units "m"; String history "2024-12-23T10:01:48Z (local files) 2024-12-23T10:01:48Z https://erddap.ogsl.ca/erddap/tabledap/mpoSgdoADCP.html"; String infoUrl "www.dfo-mpo.gc.ca/index-fra.html"; String institution "Fisheries and Oceans Canada"; String instrument_type "ADCP"; String janus "4-Beam"; String keywords "ADCP, heading, pitch, roll, temperature, water velocity"; String keywords_fr "ADCP,cap,roulis,tangage,température,vitesse du courant"; String keywords_vocabulary "GCMD Science Keywords"; String license "Open Government Licence - Canada"; String licenseUrl "https://open.canada.ca/en/open-government-licence-canada"; Float64 magnetic_declination -16.93; String magnetic_declination_units "degree east"; String naming_authority "BODC, SDC, CF, MEDS"; Float64 Northernmost_Northing 64.33323; String odf_data_type "MADCP"; String organization "IML"; String ping_type "bb"; String platform "mooring"; String platform_vocabulary "https://vocab.nerc.ac.uk/collection/L06/current/"; String publisher_email "gddaiss-dmsaisb@dfo-mpo.gc.ca"; String publisher_type "institution"; String sensor_comments "The model and serial number are the same for the temperature and pressure sensors as the ADCP."; Float64 sensor_depth 40.1; String sourceUrl "(local files)"; Float64 Southernmost_Northing 45.93898; String standard_name_vocabulary "CF Standard Name Table v70"; String subsetVariables "station, chief_scientist, cruise_number"; String summary "Data combined from archived files"; String summary_fr "Données combinées à partir de fichiers d'archive"; Float64 time_coverage_duration 129.448; String time_coverage_end "2023-10-29T15:59:59Z"; String time_coverage_start "1998-05-25T19:30:00Z"; String title "OMDS-ADCP data | SGDO-Données ADCP"; Float64 Westernmost_Easting -87.3499; } }
The URL specifies what you want: the dataset, a description of the graph or the subset of the data, and the file type for the response.
Tabledap request URLs must be in the form
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/datasetID.fileType{?query}
For example,
https://coastwatch.pfeg.noaa.gov/erddap/tabledap/pmelTaoDySst.htmlTable?longitude,latitude,time,station,wmo_platform_code,T_25&time>=2015-05-23T12:00:00Z&time<=2015-05-31T12:00:00Z
Thus, the query is often a comma-separated list of desired variable names,
followed by a collection of
constraints (e.g., variable<value),
each preceded by '&' (which is interpreted as "AND").
For details, see the tabledap Documentation.